For constant ratio for traditional wind power system with low energy utilization and poor adaptation to the external environment
the metal belt CVT is introduced as a part of traditional wind power system
the eventual of a new variable ratio wind power system is established
through numerical modeling method
the model of the new variable ratio wind power systems is built
the variation law of system parameters
performance indicators before and after introduction the metal belt CVT into wind power system is studied.The results show that metal mounting system CVT wind speed changes in the external conditions
overall power coefficient
turbine power
electric power delivered
the torque transmission shaft and energy efficiency are higher than the system is not installed
since the introduction of the metal belt CVT
the drive shaft torque before the changes become smoother than the installation
which has direct implications for increased torsional fatigue life of the drive shaft.The energy efficiency of installation metal CVT wind power system wind conditions at each interval change in energy efficiency compared to not install the system is small