Zou Shuaidong,Wang Guangjian,Xie Guanghui,et al.Analysis and Optimization on Transmission Accuracy of Shoulder Joint Reducer for an Upper Limb Rehabilitation Robot[J].Journal of Mechanical Transmission,2024,48(07):137-142.
Zou Shuaidong,Wang Guangjian,Xie Guanghui,et al.Analysis and Optimization on Transmission Accuracy of Shoulder Joint Reducer for an Upper Limb Rehabilitation Robot[J].Journal of Mechanical Transmission,2024,48(07):137-142. DOI: 10.16578/j.issn.1004.2539.2024.07.017.
Analysis and Optimization on Transmission Accuracy of Shoulder Joint Reducer for an Upper Limb Rehabilitation Robot
Based on the characteristics of high error sensitivity and large load capacity of the shoulder joint of the upper limb rehabilitation robot relative to other joints
an involute planetary reducer with small tooth number difference is applied to its shoulder joint drive in this study. Considering the main factors of transmission errors caused by machining and assembly errors
the analytical calculation model of transmission errors of the planetary reducer with small tooth number difference is established based on the mesh line increment method. From the perspective of statistics
Monte Carlo method is used to analyze the effects of eccentricity error and initial phase on the transmission accuracy of the shoulder joint of upper limb rehabilitation robots. Based on the analytical model of shoulder joint transmission accuracy
the output torque fluctuation caused by transmission error is analyzed and particle swarm optimization algorithm is adopted to optimize transmission accuracy under the condition of constant machining accuracy
so as to improve the output torque fluctuation caused by transmission error of the shoulder joint of the upper limb rehabilitation robot to avoid the secondary injury of the patients.
DING Xiaojing,WANG Yongjun,JIANG Yunhu,et al.Body composition of upper limbs for hemiplegic patients after isokinetic strength training[J].Chinese Journal of Rehabilitation Theory and Practice,2022,28(11):1265-1269.
DENG Weiwei,HOU Jingming,LIU Hongliang.Application of nerve regulation technique in rehabilitation of stroke[J].Journal of Modern Medicine and Health,2019,35(10):1445-1447.
WANG Zhuang,WANG Yizhao,QIU Shiyin,et al.Research progress of upper limb rehabilitation robot for stroke[J].China Journal of Contemporary Neurology Neurosurgery,2023,23(1):15-21.
WANG Zhanli,DUAN Zhifeng,LI Shuang,et al.Design and analysis of upper limb rehabilitation robots with fully-actuated shoulder joints[J].Journal of Mechanical Transmission,2022,46(10):42-48.
GARCIA P L,CRISPEL S,SAERENS E,et al.Compact gearboxes for modern robotics:a review[J].Frontiers in Robotics and AI,2020,7:103.
MATSUKI H,NAGANO K,FUJIMOTO Y.Bilateral drive gear—a highly backdrivable reduction gearbox for robotic actuators[J].IEEE/ASME Transactions on Mechatronics,2019,24(6):2661-2673.
MADSEN E,ROSENLUND O S,BRANDT D,et al.Comprehensive modeling and identification of nonlinear joint dynamics for collaborative industrial robot manipulators[J].Control Engineering Practice,2020,101:104462.
ZHANG Peng,CHEN Huixian,QIU Yingchi,et al.Modeling and analysis of spatial positioning error of flexible medical manipulator [J].Journal of Gansu Sciences,2022,34(5):18-25.
WANG G J,LUO Q,ZOU S D.Time-varying meshing stiffness calculation of an internal gear pair with small tooth number difference by considering the multi-tooth contact problem[J].Journal of Mechanical Science and Technology,2021,35(9):4073-4083.
YANG D C H,BLANCHE J G.Design and application guidelines for cycloid drives with machining tolerances[J].Mechanism and Machine Theory,1990,25(5):487-501.
WANG G J,CHEN L,YU L,et al.Research on the dynamic transmission error of a spur gear pair with eccentricities by finite element method[J].Mechanism and Machine Theory,2017,109:1-13.
WANG Chaobing,CHEN Xiao'an,CHEN Hong,et al.Influence of error's randomness on transmission accuracy of planetary gear[J].Journal of Chongqing University,2012,35(9):41-47.